Specification

TÜV certified according to EN 14975.

Aboma certified according to EN-ISO 14122 for access to Lift Engine Rooms

Roof hatch, type RHT1015
Standard opening size: 1000 x 1500 mm
Weight: 72 kg
Gorter® - completely assembled with:

  • Thermal separated and insulated aluminium construction
  • Counterbalancing system for assisted opening and controlled closing
  • Double sealing for water and weather tightness
  • Fully opened lid engages automatically, with release button
  • Diagonal hand rail to safely enter and leave roof hatch
  • Three point cylinder lock (31 x 60 mm) with 3 keys, in and outside operation

Performance:

  • Insulation value (EN-ISO10077-1/2): Rc = 3,2 (m2. K) W; U = 0,31 W/(m2.K)
  • Sound reduction (EN-ISO140-3): 27 dB
  • Wind and water tightness (EN1027/EN1873): 650 Pa
  • Construction strength (EN1026/EN1027): ± 3000 Pa
  • Air tightness (EN 1026): 0,5 m3/hm1
  • Snow load EN 1991-1/5): 200 kg/m2

Standard powder coating:

  • RAL 7047 (outside) and RAL 9010 (inside).


Scissor stair, type XL
Casing:

  • For structural opening size (W x L x H) 1000 x 1300 x 250 mm 
  • With sealing all around

Stair:

  • Material: cast aluminium
  • Size steps: 480 x 140 x 26 mm, anti-skid
  • Distance between steps: ca.  250 mm depending on room height
  • Steps can be levelled horizontally 

Room height: ........ mm, standard 3000 mm
to be specified from top of floor to bottom of cover.
Option: up to 3500 mm (type XL-H).
Projection while opening:
600 mm (3000 mm room height)
850 mm (3200 mm room height)
Hardware:

  • Hook and eye
  • Stair guide control system
  • 2 x Handrail, prepared for padlock, to secure retracted stairs


Extension of scissor stair in plenum (option):
The stair can de extended to bridge the distance between ceiling and roof hatch in cases where it is mounted in a suspended ceiling/plenum

Options

electrical_operationDepending on door type, cover weight and other requirements we can install one or more rack-and-pinion drives. These drives are available in 24 Vdc or 230 Vac
Operation and control 230Vac
This system is controlled with a surface mounted or built-in switch. Operation of two drives through one switch is possible.
Operation and control 24Vdc
Operation of one or more drives is controlled by a control box with rectifier that is connected to the electricity network.
Features

  • communication with central alarm system
  • emergency switch
  • certified for smoke vent system / fire resisting system
  • programmable
  • operation control of other objects
  • control by automatic detectors - smoke, rain, wind, fire etc.
  • automatic sequence control of two covers that are overlapping
  • automatic stop in case of unequal load or overload
  • etc.
Depending on the features we will recommend a suitable control box type.
Emergency hatches and doors:
It is of life importance that an emergency door opens after a break down of the electrical system. For those reasons a control box can be provided with a built-in emergency power pack.
If the emergency situation is very critical it advisable to apply doors that can be manually operated after a total break down of electrical network system and the emergency power pack.
Electrical installation:
Roof Hatches and Floor Doors will be supplied with drives installed together with required options as control box, switches, detectors, installation drawings and electrical diagrams. Electrical installation should be carried out by an electrical contractor.

safety_railingPartition and marking of safe area on the roof
Components:

  • Rail post, straight, with base plate, net height ca. 1000 mm
  • Rail post, angle, with base plate, net height ca. 1000 mm
  • Hand rail
  • Knee rail
Material:
Aluminium
Supply:
In components
Installation:
Roof surface mounted
Mounted on concrete slabs (supplied by others)


plenum_2_stepsExtension of types Large, EI-60 and XL

 

Safety Approval Report(EN-ISO 14122-3) available

Height: ........mm
to be specified from ceiling to roof hatch flange or roof deck.
Stairs:
Material: aluminium
Steps are anti-skid
Size steps: 360 x 140 x 26 mm (types Large and EI-60)
Size steps: 480 x 140 x 26 mm (type XL)
Steps can be horizontally adjusted

Hardware:
Brackets