Gorter® - completely assembled:
Standard dimensions - weight:
600 x 600 mm / 24 kg
800 x 800 mm / 30 kg
1000 x 1000 mm / 48 kg
1000 x 1500 mm / 103 kg
1000 x 2000 mm / 125 kg
Longest side is hinge side
Special dimensions (mm):
........ x ........ mm
Load:
7,5 kN/m2 (according to EN1991)
Hardware:
Installation:
Welded strap anchors
Standard Electrical operation - GT35
The Gorter GT35 electrical operation is a solution, which can be fitted on floor door of the type WA, WAPT and OP. The two powerful electric motors are always fitted as a pair on both sides of the lid.
Suitable for
Operation and control 230Vac
The Gorter GT35 is a system with two motors and a control unit. The system comes standard with a wireless remote control and a compact control panel. The keypad connected with signal cable can be installed remote from control unit.
Dimensions:
Control unit: 265 x 105 x 40 mm
Keypad: +/- 70 x 50 x 10 mm
Length of signal/power cable motors: 2 m
Electrical installation:
The drives and the wiring must be installed by a certified installer
Operation for a hatch with double lids
Depending on the access door type, the weight of the cover and the application, we can install one or more gear rack drives. These drives are available in 24 Vdc or 230 Vac.
Operation and control 230Vac
This is the simplest system with 1 motor. It can be operated with an integrated or surface-mounted switch, not included.
Operation and control 24Vdc
Operation of one or more drives is controlled by a control box with rectifier that is connected to the electricity network.
Features
Depending on the features we will recommend a suitable control box type.
Emergency hatches and doors:
It is of life importance that an emergency door opens after a break down of the electrical system. For those reasons a control box can be provided with a built-in emergency power pack.
Electrical installation:
The drives and the wiring must be installed by a certified installer.
Documentation:
Overview brochure1.93 MB
Technical Data Sheet - Reset / Calibration GT35 / GT50202.93 KB
WAPT declaration of performance 266.19 KB
Manuals:
User information floor door hinged2.12 MB
Drawings:
Acrobat |
AutoCAD .dwg |
Sketchup .skp |
REVIT .rfa |
REVIT
.rvt |
REVIT
.ifc |
|
WAPT-600-600 | |
|||||
WAPT-800-800 | ||||||
WAPT-1000-1000 | ||||||
WAPT-1000-1500 | ||||||
WAPT-1000-2000 | ||||||
WAPTD |
Watch the Revit instruction video
The Gorter WAPT hinged floor door provides practical and safe access to the areas below. The pan-type cover is suitable for pouring cement followed by tiling or the laying of floor covering (carpet, laminate, etc.).
The reinforcing mesh supplied is placed in the cover when pouring cement. The cover is made of anodised aluminium, and the hatch is suitable for both inside and outside use. The powder-coated steel frame has an optional connection for a drainage system / rain water discharge.
The Gorter hinged aluminium floor door with recessed cover is available in five standard sizes as well as special sizes.
Depending on the size and application, WAPT floor doors can be combined with a Gorter fixed vertical ladder, an extension ladder or a fixed staircase. A scissor stair can be used in some cases.
Hinged floor doors are not recommended in situations subject to dynamic loads. The floor door is optionally available to support loadings specified by the customer.
+