Gorter® - completely assembled:
Dimensions - weight:
600 x 600 mm / 19 kg
800 x 800 mm / 28 kg
1000 x 1000 mm / 36 kg
1000 x 1500 mm / 52 kg
1000 x 2000 mm / 65 kg
Longest side is hinge side
Special dimensions (mm):
........ x ........ mm
Dimensions > 1000 x 2500 with 2 lids (D = 2 lids)
Load:
15 kN/m² with EN1991
Hardware:
Installation:
Standard Electrical operation - GT35
The Gorter GT35 electrical operation is a solution, which can be fitted on floor door of the type WA, WAPT and OP. The two powerful electric motors are always fitted as a pair on both sides of the lid.
Suitable for
Operation and control 230Vac
The Gorter GT35 is a system with two motors and a control unit. The system comes standard with a wireless remote control and a compact control panel. The keypad connected with signal cable can be installed remote from control unit.
Dimensions:
Control unit: 265 x 105 x 40 mm
Keypad: +/- 70 x 50 x 10 mm
Length of signal/power cable motors: 2 m
Electrical installation:
The drives and the wiring must be installed by a certified installer
Operation for a hatch with double lids
Depending on the access door type, the weight of the cover and the application, we can install one or more gear rack drives. These drives are available in 24 Vdc or 230 Vac.
Operation and control 230Vac
This is the simplest system with 1 motor. It can be operated with an integrated or surface-mounted switch, not included.
Operation and control 24Vdc
Operation of one or more drives is controlled by a control box with rectifier that is connected to the electricity network.
Features
Depending on the features we will recommend a suitable control box type.
Emergency hatches and doors:
It is of life importance that an emergency door opens after a break down of the electrical system. For those reasons a control box can be provided with a built-in emergency power pack.
Electrical installation:
The drives and the wiring must be installed by a certified installer.
Documentation:
Overview brochure1.93 MB
Technical Data Sheet - Reset / Calibration GT35 / GT50202.93 KB
Manuals:
User information floor door hinged2.12 MB
Technical data and drawings:
Acrobat |
AutoCAD .dwg |
Sketchup .skp |
REVIT .rfa |
REVIT
.rvt |
REVIT
.ifc |
|
WA-600-600 | |
|||||
WA-800-800 | ||||||
WA-1000-1000 | ||||||
WA-1000-1500 | ||||||
WA-1000-2000 | ||||||
WAD |
Watch the Revit instruction video
The Gorter WA hinged floor door provides practical and safe access to the areas below. The cover and frame are made of anodised aluminium, and the hatch is suitable for both inside and outside use. The frame has an optional connection for a drainage system / rain water discharge.
The Gorter hinged aluminium floor door with checker plate cover is available in five standard sizes as well as special sizes. Sizes larger than 1,000 x 2,500 mm have two covers.
Depending on the size and application, WA floor doors can be combined with a Gorter extension ladder or a fixed staircase.
Hinged floor doors are not recommended in situations subject to dynamic loads. The floor door is optionally available to support loadings specified by the customer.
+