Explosion-release roof hatch, expl. vent/hatch for roof installation

Image

Explosion vent for installation on roofs

Specifications

CE ETA-15/0338

KOMO:SKG.0372.0503

 

Also applicable for roof access.
Type - Standard opening size in mm:
RHTX1010 - 1000 x 1000 / 58 kg
RHTX1015 - 1000 x 1500 / 72 kg
RHTX1020 - 1000 x 2000 / 87 kg
Special size:........ x ........ mm

Gorter® - completely assembled, surface mounted with:

  • Insulated aluminium construction
  • Counterbalancing system for assisted opening and controlled closing
  • Diagonal hand rail on lid inside to safely enter and leave roof hatch
  • Double sealing for water and weather tightness
  • Fully opened lid engages automatically, with release button
  • Lock: ERC-Explosion Release Control, inside operation.
  • ERC-Explosion Release Control: release at a pressure increase > 1,0 kN on inside lid (Patent No. 1870542)

Performance according to CE (ETA-15/0338):

  • Resistance to permanent loads (Eurocode EN 1993-1-1): 1050 kg/m²
  • Insulating (EN-ISO10077-2): Uw ≤ 0.32 W/(m².K)

  • Sound reduction (EN-ISO140-3): 26 dB
  • Watertightness (EN 12208): Class E 650
  • Resistance to wind load (EN 12210): Class E 3000
  • Resistance to snow loads (EN 1991-1-3): 3.97kN/m²
  • Impact hard body (EN 356): Class P5A
  • Impact soft body (EN 13049): Class 5
  • Air permeability (EN 12207): Class 3

Standard powder coated:

  • RAL7047 (outside) and RAL9010 (inside)

Quote request

1
2
Products

This field is required!

Roof hatches

This field is required!

Floor doors

This field is required!

Wall- and ceiling doors

This field is required!

Ladder or stairs

This field is required!

Ladder or stairs

This field is required!

Type scissor stairs

This field is required!

Floor height fixed stairs

This field is required!

RHTG Floor height fixed stairs

This field is required!

Request a quotation: RHT roof hatch
Request a quotation: RHT roof hatch with ladder
Request a quotation: RHT roof hatch with scissor stairs
Request a quotation: RHT roof hatch with electric scissor stairs
Request a quotation: RHT roof hatch with scissor stairs EI-60
Request a quotation: RHT roof hatch with fixed stair GS50
Request a quotation: RHT roof hatch with fixed stair GS55
Request a quotation: RHT roof hatch with fixed vertical ladder
Request a quotation: RHTG Roof hatch
Request a quotation: RHTG roof hatch with fixed stair GS50
Request a quotation: RHTG roof hatch with fixed stair GS55
Request a quotation: RHTEI roof hatch
Request a quotation: RHTEP roof hatch
Request a quotation: RHTX roof hatch
Request a quotation: WA Floor door flush
Request a quotation: WAPT Floor door recessed cover flush
Request a quotation: WAEI Floor door fire rated flush
Request a quotation: WAG glass floor door
Request a quotation: OP Floor door surface mounted
Request a quotation: U Wall door Universal
Request a quotation: B Wall door fire rated
Request a quotation: EXW Explosion vent
Data roof hatch
Data floor doors
Data wall- and ceiling doors
Type roof hatch:

This field is required!

Type roof hatch:

This field is required!

Type roof hatch:

This field is required!

Type roof hatch:
This field is required!

Type roof hatch:
This field is required!

Type roof hatch:

This field is required!

Type roof hatch:

This field is required!

Type roof hatch:

This field is required!

Invalid Input

Type roof hatch:

This field is required!

Type roof hatch:

This field is required!

Type roof hatch:

This field is required!

Type roof hatch:

This field is required!

Type roof hatch:

This field is required!

Type roof hatch:

This field is required!

Type WA:

Invalid Input

Type WAPT:

Invalid Input

Type WAEI:

Invalid Input

Type WAG:

Invalid Input

Type OP:

Invalid Input

Type U

Invalid Input

Type B

Invalid Input

Dimensions to be specified:
Invalid Input

Enter below the floor height. Measured from top of finished floor to top unfinished roof.
Floor Height in mm:
This field is required!

Enter below the ceiling height. Measured from top of finished floor to bottom (lower) ceiling.
Ceiling Height in mm:
This field is required!

Options:

Invalid Input

Options:

Invalid Input

Number of products:
This field is required!

Your data
You are a:
Invalid Input

Company name:
This field is required!

Contact name:
This field is required!

Tel:
This field is required!

E-mail:
This field is required!

Project:
This field is required!

Place Project:
This field is required!

Comment (optional):
Invalid Input

This field is required!

Processing

 

An explosion vent roof hatch - also known as an explosion vent or explosion hatch - has an Explosion Release Control (ERC) which ensures that the hatch unlocks automatically in the event of an unexpected pressure build-up. The opening pressure is 100 kg. In addition to explosion vent roof hatches, Gorter also supplies explosion vent hatches for façades.

 

Explosion vent hatch usage

Gorter explosion vent roof hatches can be installed on flat roofs with any pitch. The cover of the hatch must not be impeded by obstacles inside or out.

 

Fully thermally broken

The Gorter explosion vent roof hatch has a fully thermally isolated curb and cover, and a proven high insulation value. This minimises the chance of condensation forming and guarantees energy cost savings.

 

Gorter explosion hatch/pop hatch/explosion vent roof hatch:

  • In standard and special sizes
  • TÜV NORD, KOMO® certified and Aboma safety mark
  • EN 1991-1-7:2006
  • Gorter Explosion Release Control (ERC), European patent no. 1870542
  • Fully thermally broken curb and cover
  • 10-year warranty on the roof hatch
  • Fast delivery
  • High-quality aluminium construction 3x lighter than steel, strong and corrosion-free
  • Burglar- and sound-proof

Note: the size of the explosion vent opening should be calculated by an expert engineer.