Roof hatch RHT7014 with scissor stair EI-60, fire rated 60 minutes

Image

Combination: roof hatch type RHT7014 and scissor stair type EI-60, fire rated

Video

Specifications

CE ETA-15/0338
KOMO:SKG.0372.0503
Aboma certificate
TÜV NORD certified according to EN 14975:2010, with label ''Baumuster geprüft"

 

Roof hatch, type RHT7014
Standard opening size: 700 x 1400 mm
Weight: 52 kg
Gorter® - completely assembled with

  • Thermal separated and insulated aluminium construction
  • Counter balancing system for assisted opening and controlled closing
  • Diagonal hand rail to safely enter and leave roof hatch
  • Double sealing for water and weather tightness
  • Fully opened lid engages automatically, with release button
  • Cylinder lock (31 x 70 mm) with 3 keys, in- and outside operation, with 1 point lock

Performance according to CE (ETA-15/0338):

  • Resistance to permanent loads (Eurocode EN 1993-1-1): 1050 kg/m²
  • Insulating (EN-ISO10077-2): Uw ≤ 0.32 W/(m².K)

  • Sound reduction (EN-ISO140-3): 26 dB
  • Watertightness (EN 12208): Class E 650
  • Resistance to wind load (EN 12210): Class E 3000
  • Resistance to snow loads (EN 1991-1-3): 3.97kN/m²
  • Impact hard body (EN 356): Class P5A
  • Impact soft body (EN 13049): Class 5
  • Air permeability (EN 12207): Class 3

Standard powder coating:

Powder coated in RAL7047 (outside) and RAL9010 (inside).


Scissor stair, type EI 60 - fire rated

KOMO:SKG.0372.0457

Fire rating classification: EI-60 according to EN 1634-1

 

Casing:

  • For structural opening size (W x L x H): 700 x 1200 x 250 mm

Room height: ........ mm, standard 3000 mm.
to be specified from top of floor to bottom of cover.

Option: up to 3500 mm (type Large-H).

Stair:

  • Material: cast aluminium
  • Size steps: 360 x 140 x 26 mm, anti-skid
  • Step distance: ca. 250 mm depending on room height
  • Horizontal position of steps can be adjusted

Projection while opening:
600 mm (room height 3000 mm)
700 mm (room height 3200 mm)
Hardware:

  • Hook and eye
  • Handrail prepared for padlock to secure retracted stairs
  • Stair guide control system


Extension of scissor stair in plenum (option):

The stair can be extended to bridge the distance between ceiling and roof hatch in cases where it is mounted in a suspended ceiling/plenum

Options

Gorter® Electrical Operation of Roof Hatches and Floor Doors

Standard Electrical operation - GT35

electrical operation gt35The Gorter GT35 electrical operation is a solution, which can be fitted on any standard Gorter RHT roof hatch or floor door of the type WA, WAPT and OP. The two powerful electric motors are always fitted as a pair on both sides of the lid. The motors are pre-fitted from the factory or can be fitted afterwards on any standard RHT roof hatch from model year 2012 and later.

 

Suitable for

  • Roof hatches type RHT
  • Hinged Floor doors type WA (flush), WAPT and OP

 

Operation and control 230Vac

The Gorter GT35 is a system with two motors and a control unit. As a standard the system is supplied with a compact surface mount keypad for easy operation. The keypad connected with signal cable can be installed remote from control unit. On request the system can be supplied with wireless remote control.

Dimensions:

Control unit: 265 x 105 x 40 mm

Keypad: +/- 70 x 50 x 10 mm

Length of signal/power cable motors: 2 m

Electrical installation:

The drives and the wiring must be installed by a certified installer

 

Electrical operation for linking to a fire alarm systems

electrical_operation

Depending on the access door type, the weight of the cover and the application, we can install one or more gear rack drives. These drives are available in 24 Vdc or 230 Vac.
Operation and control 230Vac

This is the simplest system with 1 motor. It can be operated with an integrated or surface-mounted switch, not included.
Operation and control 24Vdc
Operation of one or more drives is controlled by a control box with rectifier that is connected to the electricity network.
Features

  • Communication with central alarm system, possibly combined with emergency switch
  • Programmable
  • Operation control of other objects
  • Control by automatic detectors - smoke, rain, wind, fire etc.
  • Automatic sequence control of two covers that are overlapping
  • Automatic stop in case of unequal load or overload
  • etc.

Depending on the features we will recommend a suitable control box type.
Emergency hatches and doors:
It is of life importance that an emergency door opens after a break down of the electrical system. For those reasons a control box can be provided with a built-in emergency power pack.
Electrical installation:

The drives and the wiring must be installed by a certified installer.


Extension Scissor Stairs - Attic Ladder - Type EI-60

plenum_2_stepsExtension of types Large, EI-60 and XL

 

Safety Approval Report(EN-ISO 14122-3) available

Height: ........mm
to be specified from ceiling to roof hatch flange or roof deck.
Stairs:
Material: aluminium
Steps are anti-skid
Size steps: 360 x 140 x 26 mm (types Large and EI-60)
Size steps: 480 x 140 x 26 mm (type XL)
Steps can be horizontally adjusted

Hardware:
Brackets

More information? Please click Products > Ladders and stairs > Extension of scissor stairs - attic ladder


Quote request

1
2
Products

This field is required!

Roof hatches

This field is required!

Floor doors

This field is required!

Wall- and ceiling doors

This field is required!

Ladder or stairs

This field is required!

Ladder or stairs

This field is required!

Type scissor stairs

This field is required!

Floor height fixed stairs

This field is required!

RHTG Floor height fixed stairs

This field is required!

Request a quotation: RHT roof hatch
Request a quotation: RHT roof hatch with ladder
Request a quotation: RHT roof hatch with scissor stairs
Request a quotation: RHT roof hatch with electric scissor stairs
Request a quotation: RHT roof hatch with scissor stairs EI-60
Request a quotation: RHT roof hatch with fixed stair GS50
Request a quotation: RHT roof hatch with fixed stair GS55
Request a quotation: RHT roof hatch with fixed vertical ladder
Request a quotation: RHTG Roof hatch
Request a quotation: RHTG roof hatch with fixed stair GS50
Request a quotation: RHTG roof hatch with fixed stair GS55
Request a quotation: RHTEI roof hatch
Request a quotation: RHTEP roof hatch
Request a quotation: RHTX roof hatch
Request a quotation: WA Floor door flush
Request a quotation: WAPT Floor door recessed cover flush
Request a quotation: WAEI Floor door fire rated flush
Request a quotation: WAG glass floor door
Request a quotation: OP Floor door surface mounted
Request a quotation: U Wall door Universal
Request a quotation: B Wall door fire rated
Request a quotation: EXW Explosion vent
Data roof hatch
Data floor doors
Data wall- and ceiling doors
Type roof hatch:

This field is required!

Type roof hatch:

This field is required!

Type roof hatch:

This field is required!

Type roof hatch:
This field is required!

Type roof hatch:
This field is required!

Type roof hatch:

This field is required!

Type roof hatch:

This field is required!

Type roof hatch:

This field is required!

Invalid Input

Type roof hatch:

This field is required!

Type roof hatch:

This field is required!

Type roof hatch:

This field is required!

Type roof hatch:

This field is required!

Type roof hatch:

This field is required!

Type roof hatch:

This field is required!

Type WA:

Invalid Input

Type WAPT:

Invalid Input

Type WAEI:

Invalid Input

Type WAG:

Invalid Input

Type OP:

Invalid Input

Type U

Invalid Input

Type B

Invalid Input

Dimensions to be specified:
Invalid Input

Enter below the floor height. Measured from top of finished floor to top unfinished roof.
Floor Height in mm:
This field is required!

Enter below the ceiling height. Measured from top of finished floor to bottom (lower) ceiling.
Ceiling Height in mm:
This field is required!

Options:

Invalid Input

Options:

Invalid Input

Number of products:
This field is required!

Your data
You are a:
Invalid Input

Company name:
This field is required!

Contact name:
This field is required!

Tel:
This field is required!

E-mail:
This field is required!

Project:
This field is required!

Place Project:
This field is required!

Comment (optional):
Invalid Input

This field is required!

Processing

 

Gorter roof hatches with scissor stairs provide practical and safe access to flat roofs for maintenance work or other purposes. The roof hatch can be installed on flat roofs with a maximum pitch of 30°.

 

Access to the roof

The Gorter combination of roof hatch and Large fireproof scissor stair provides generous access to the roof and is available for ceiling heights of max. 3,000. The roof hatch has an opening of 700 x 1,400 mm.

 

Fire-resistant EI-60 scissor stair

In this combination, the scissor stair is fire-resistant, with an EI-60 class. The roof hatch is a standard Gorter RHT7090 roof hatch. If a higher fire class is required, Gorter can also supply fully fire-resistant roof hatch with an EI120 class.

 

Scissor stair ensures free space under the roof hatch

Roof hatches combined with a scissor stair are ideal for applications where occasional but also frequent access to the roof is required. When the scissor stair is folded, you always have free space under the hatch.

 

Fully thermally broken

The Gorter RHT roof hatch has a fully thermally broken curb and cover, and a proven high insulation value of Uw ≤ 0.319 W/(m².K) This minimises the chance of condensation forming and guarantees energy cost savings. 

 

Gorter RHT roof hatch with fire-resistant scissor stair:

  • Roof hatch is CE (ETA-15/338), TÜV NORD, Aboma and KOMO® certified  with fully thermally broken curb and cover
  • Scissor stair with EI-60 class
  • Roof hatch safe operation with one hand
  • Safe grip all the way to the roof
  • 10-year warranty on the roof hatch, 1 year on climbing devices

  • Roof hatch with optional electric control
  • High-quality aluminium construction of roof hatch and scissor stair
  • Euro cylinder lock with indoor and outdoor operation
  • Burglar- and sound-proof roof hatch
  • Fast delivery

Scissor stair extension for plenum

The fire-resistant scissor stair can be used with an extension of scissor stair to bridge a plenum (= space between suspended ceiling and roof).

 

Read more about the advantages of Gorter roof hatches here